VSG - 24001 - LIFT LD - electrical motor kit - EN - IT - FR - DE - ES
SUBJECT: REPLACEMENT OF ELECTRIC MOTOR FOR 2-POST LIFTS PRE
UNITED SERIES
Description:
1. The 900003001 and 900003060 electric motors are replaced by the kits listed in the
following table for the pre United series electromechanical 2-column lifts (pre
Legend/Tomorrow).
The 047097860 and 047097870 kits include electric motor + set of electrical cables.
2. In the lifts of the new United series, the new motors are interchangeable without making
any changes to the system.
| Motor | Lift Series | New Kit/Motor |
| 900003001 (3.5kw) | Pre United | 047097860 |
| 900003060 (2.6kw) | Pre United | 047097870 |
| 900003001 (3.5kw) | United | 900005250 |
| 900003060 (2.6kw) | United | 900005260 |
MOTOR CABLE IDENTIFICATION FOR THE PRE UNITED SERIES:
In the kits there are 4 sets of motor cables of different lengths, choose the most appropriate
cable by comparing it with the cable to be replaced, below are the indications.
047068050
- Cable length 1400mm, which connects the motor of the control column to the electrical
panel.
- Connect the phases U1, V1, W1 in the contactor as in the cable to be replaced.
- For the heat probe cables, follow the cable coloring (in the cables to be replaced there
were veins 4 and 5) then:
Replacement cable (white vein) -> Replacement cable (4 vein)
Replacement cable (red vein) -> Replacement cable (5 vein)
047067192
- Cable length 600mm, which connects the motor of the opposite column to the junction
box.
- Connect the U2, V2, W2 phases in the contactor as in the cable to be replaced.
- The heat probe cables, connect in the terminals as connected in the cable to be
replaced.
047066764
- Cable length 7700mm, which connects the motor of the opposite column to the
electrical panel.
- Connect the U2, V2, W2 phases in the contactor as in the cable to be replaced.
- The heat probe cables, connect in the terminals as connected in the cable to be
replaced.
046410593
- Cable length 7200mm, which connects the motor of the opposite column to the
junction box.
- Connect the U2, V2, W2 phases in the contactor as in the cable to be replaced.
- The heat probe cables, connect in the terminals as connected in the cable to be
replaced.